The Model 9623-H2O is an easy to operate system designed to be used This monitor allows for the precision testing of water tested containment isolation valves using plant demin or service water. This unit comes with 2 or three flow ranges, depending on your site-specific needs and two pressure channels, one to monitor inlet pressure and one for your test pressure.
The 9623-H2O quantifies the component under test’s leakage rate by maintaining a constant water pressure against the barrier being tested while measuring the water flow rate needed in order to maintain that pressure constant. A steady supply at a constant pressure of clean water is required to operate.