Heat Exchanger Testing Services by Graftel, Inc.
Graftel has over 14 years of
support experience proving both equipment and on-site services to the
nuclear power industry. Our specialty is the conduct of Integrated
Leakage Rate Tests (ILRT).
This test, like heat exchanger performance testing, requires the onsite
installation of instrumentation and data collection of information.
This information is processed using quality software to calculate
parameters used to satisfy acceptance criterion which satisfy plant
technical specification requirements.
Graftel’s approach to heat exchanger testing and analysis is consistent
with the methodology presented in the EPRI document TR-107397, “Service
Water Heat Exchanger Testing Guidelines.”
The testing services provided support the site’s heat exchanger testing
program while keeping it consistent with EPRI guidelines utilizing the
four step method outlined below
1. Test plan development A testing plan is developed that
includes the below items:
-
Establish the test objectives,
acceptance criterion, analytical methodology, test conditions and
overall target test uncertainty
-
Specification of measurement system
and test methodology
-
Test uncertainty analysis
2. Test procedure development The test procedure is developed in
accordance with utility specific procedure requirements. The test
procedure will provide the step-by-step process for ensuring the
requirements of the test plan are carried out in a manner that will
ensure the test is conclusive.
The procedure will include instructions for proper installation of
required sensors so that their performance stays within criteria
specified by the test plan.
3. Test implementation. This includes PCs loaded with data
collection software, all required instrumentation and cabling,
instrument calibration, on-site support installing instrumentation;
obtaining and re-cording all test data as well as providing
recommendations for operations personnel in establishing optimum system
configurations and heat loads.
4. Performance evaluation This evaluation includes the following
key elements: -Statistical analysis of the test data reducing it to a
set of input parameters for thermal performance analysis.
-
Thermal performance analysis
utilizing PROTO-HX™ or a utility-provided analytical pack-age.
-
A detailed post-test uncertainty
analysis that provides the 95 percent confidence range around the
calculated heat exchanger performance parameter.
-
A final test report containing the
above information.
Graftel, Inc. maintains an
Appendix B QA program implementing 10 CFR 50 Part 21. Our calibration,
software and engineering services have been recently audited and
recorded in the NUPIC database.
In addition, Graftel’s is an accredited ISO 17025 instrument calibration
laboratory, certified by LAB. Graftel’s team of recently nuclear plant
badged personnel are instrumentation, calibration and data collection
experts.
Proto-Power’s engineering services are subcontracted by Graftel. They
provide heat exchanger expertise as well as the analysis software,
(PROTO-HX) which is recognized as the industry standard. Their personnel
have extensive experience in heat exchanger testing.
These activities include one or more of the following activities for each
listed heat exchanger: heat exchanger model development, test protocol
document development, test procedure development, on-site test support,
test result analysis, and/or test uncertainty analysis:
Indian Point 3:
Emergency Diesel Generator Coolers (3)
Containment Fan Cooler Units (5)
LaSalle Units 1 & 2:
ECCS Equipment Room Coolers (8)
Emergency Diesel Generator Coolers (5)
RHR Heat Exchangers (4)
Spent Fuel Pool Coolers (4)
Millstone Point Unit 2:
Emergency Diesel Generator Heat Exchangers (6)
Vital AC Switchgear Room Coolers (3)
Vital DC Switchgear Room Chiller Condensers (2)
RBCCW Heat Exchanger (3)
Millstone Point Unit 1:
Emergency Diesel Generator Heat Exchangers (3)
Low Pressure Coolant Injection Heat Exchanger (2)
RBCCW Heat Exchanger (3)
TBCCW Heat Exchanger (2)
D. C. Cook:
Emergency Diesel Generator Coolers (3)
CCW Heat Exchanger (2)
Please feel free to contact us at
847-364-2600 if you have any questions.
|